Frequency Response of Piezo Buzzer

Frequency Response of Piezo Buzzer

1. Aim

To measure acoustic output versus drive frequency of a piezo buzzer and identify its resonant frequency region.


2. Apparatus / Components Required

  • SEELab3 unit
  • Piezo buzzer
  • Microphone/sound sensor
  • Connecting wires
  • Data capture interface

3. Theory & Principle

Piezo buzzers show non-uniform response with frequency. Output intensity peaks near mechanical resonance determined by buzzer structure and enclosure.

By sweeping frequency and measuring microphone amplitude, we obtain response curve: \[A = f(\nu)\]

Peak of this curve corresponds to resonance frequency.


4. Circuit Diagram / Setup

  1. Connect piezo buzzer to waveform output.
  2. Place microphone at fixed distance from buzzer.
  3. Ensure constant geometry during sweep.
  4. Open frequency-response measurement screen.

5. Procedure

  1. Set sweep range (e.g., 1 kHz to 5 kHz).
  2. Run sweep and record microphone amplitude at each step.
  3. Plot amplitude vs frequency.
  4. Identify resonance peak and bandwidth around peak.
  5. Repeat once for consistency check.


6. Observation Table

Frequency (Hz)Amplitude (arb.)
1000 
1500 
2000 
2500 
3000 
3500 
4000 
4500 
5000 

7. Results and Discussion

  • Frequency response was non-uniform as expected.
  • Peak response occurred near ____ Hz (resonant zone).
  • Away from resonance, output amplitude dropped significantly.

8. Precautions

  1. Keep microphone distance fixed throughout sweep.
  2. Avoid reflections from nearby hard surfaces where possible.
  3. Use same gain settings for all readings.

9. Troubleshooting

SymptomPossible CauseCorrective Action
Flat response curveMicrophone clipping/low sensitivityAdjust mic gain and verify connection
Irregular spikesEnvironmental noise/reflectionsRepeat in quieter open area
No clear resonanceDefective buzzer or too narrow sweepExpand sweep range and test buzzer

10. Viva-Voce Questions

Q1. Why can't ExpEYES directly drive an 8 Ohm loudspeaker from sine output?

Ans: The source cannot supply the high current demanded by low-impedance loads; piezo is a higher-impedance alternative.

Q2. What is resonant frequency in this context?

Ans: Frequency at which buzzer mechanical-electrical coupling gives maximum output amplitude.